Silverliner Rainscreen Cavity Barrier

RSCB
£15.58 inc. tax

£12.98 ex. tax
? Tax based on United Kingdom.
Pack Size*
Notify me when product is back in stock
Silverliner Rainscreen Cavity Barrier Summary

Silverliner Rainscreen Cavity Barrier

This has been developed to protect the voids between the outer rainscreen cladding / facade and the inner construction element
of the building.

Choice of Ventilated or Non Ventilated 
Includes Brackets
Dimensions 75mm thickness x 1000mm long
Width 100mm - 200mm
Made to order so please allow 10-14 days for delivery.

The advantages of the Silverliner Cavity Barrier are as follows:

• Fire Resistant testing to BS 476 - 60 & 120mins.

• Air Permeability testing to EN 1026 to 600Pa.

• Acoustic Isolation testing to EN 10140 to 39dB (non ventilated).

• Suitable to close up to 25mm ventilation gap (50mm gap is available).

• Voids up to 450mm wide.

• Dynamic movement testing 500 cycles per 30 minutes (non ventilated).

• Available in Pre-Cut Sections for ease of application with minimum waste to suit void size.

• Superior Level of Sustainability.

• Encased Fibre Migration for Air Plenium Use.

• Free of halogens, asbestos, fibres and silica and is non toxic.

• Brackets included in the pack.

• Life expectancy of over 25 years.

• Contributes to Green Building.

• Softer feel, Odourless and Easy to Cut.

• Light Weight.

Silverliner Cavity Barrier - Ventilated
This Cavity Barrier comprises of a structural stone wool with aluminium foil on the surrounding faces, with a integral intumescent strip bonded to
the one of the outer faces wrapped to ensure the intumescent isn't effected by moisture. In the event of a fire the intumescent will react to the
exposure to heat and rapidly expand to fill the air gap originally left in the void.

Silverliner Cavity Barrier - Non - Ventilated
This Cavity Barrier just like the above on comprises of a structural stone wool with alluminium foil on the surrounding faces, however where the intumescent strip is bonded there now is a elastromeric flexible intumescent strip bonded that will accommodate or the movement of the building. The Elastromeric intumescent is then encased to prevent moisture ingress. In the event of a fire the intumescent will react to the exposure to heat and rapidly expand solidify the gap filled by the elastromeric intumescent.

Made to order so please allow 10-14 days for delivery.

Please read data sheet for more information on this product.

DATA SHEET

INSTALLATION MANUAL

All orders are usually despatched within 24 hours of receiving cleared payment (Mon–Fri).

The above information is based on current test data, health and safety information and application instructions supplied by our suppliers and manufacturers of the products. It is supplied for guidance and to the best of our knowledge is true and accurate. Customers should satisfy themselves to the suitability of the products in its intended use and no guarantee is given or implied as the conditions of actual use are beyond our control. If in doubt the customer should consult the designer of the project or the local building control. 

Fire Stopping Shop, disclaim any liability for loss, damage or other expense which may arise from the use of this information, data or products refereed to and reserve the right to amend or change any details without notice. This statement does not affect your statuary rights.  