Carboline Phenoline 1205 10L Kit
Carboline Phenoline 1205 10L Kit
Phenoline 1205 Glass flake-filled coating with dense cross-linking that exhibits excellent overall chemical resistance to a variety of aggressive chemicals. Glass reinforcement provides added abrasion resistance, permeation resistance and internal reinforcement. 1205 exhibits very good acid resistance. Excellent for use as a lining for tanks or pipes in process facilities where hot water or abrasive conditions exist.
Product Features
- Excellent resistance to ethanol, gasoline, jet fuels and solvents.
- Excellent abrasion resistance.
- Excellent thermal shock resistance (0 to 300° F).
- VOC compliant to current AIM regulations.
- Excellent resistance to deionized or demineralized water up to 203°F (95°C).
- Excellent resistance to crude oil up to 250°F (121°C).
- Excellent for crude oil storage and transportation up to 250° F (121° C)
- Recommended for CS-1,3,4 and SS-1,2,3 systems of NACE SP0198 Standard Practice for coatings to control Corrosion Under Insulation (CUI).
| Color | Red (0500); Grey (5742) |
| Finish | Satin |
| Primer | Self-priming. May be applied over epoxies and phenolics as recommended. |
| Dry Film Thickness | 6 - 8 mils (152 - 203 microns) mils per coat. Can be applied up to 18 mils DFT per coat, as needed. 12 mils DFT minimum for Immersion Service Do not exceed 18 mils DFT in a single coat Do not exceed 30 mils total DFT |
| Solids Content | By Volume 70% +/- 2% |
| Theoretical Coverage Rate |
1123 ft²/gal at 1.0 mils (27.6 m²/l at 25 microns) 187 ft²/gal at 6.0 mils (4.6 m²/l at 150 microns) 140 ft²/gal at 8.0 mils (3.4 m²/l at 200 microns) Allow for loss in mixing and application. |
| VOC Value(s) | Thinner 2 : 13 oz/gal: 2.54 lbs/gal (305 g/l) Thinner 213 : 13 oz/gal: 2.58 lbs/gal (308 g/l) As Supplied : 2.08 lbs/gal (250 g/l) These are nominal values. |
| Dry Temp. Resistance | Continuous: 425°F (218°C) Non-Continuous: 450°F (232°C) Discoloration is observed above 200°F (93°C) |
| Limitations | For immersion applications, metal tanks should be insulated if operating temperature exceeds 140°F (60°C). |
Data Sheets
Phenoline 1205 PDS
The above information is based on current test data, health and safety information and application instructions supplied by our suppliers and manufacturers of the products. It is supplied for guidance and to the best of our knowledge is true and accurate. Customers should satisfy themselves to the suitability of the products in its intended use and no guarantee is given or implied as the conditions of actual use are beyond our control. If in doubt the customer should consult the designer of the project or the local building control.
Fire Stopping Shop, disclaim any liability for loss, damage or other expense which may arise from the use of this information, data or products refereed to and reserve the right to amend or change any details without notice. This statement does not affect your statuary rights.
AED
AFN
ALL
AMD
ANG
AOA
ARS
AUD
AWG
AZN
BAM
BBD
BDT
BGN
BHD
BIF
BMD
BND
BOB
BRL
BSD
BTN
BWP
BYN
BZD
CAD
CDF
CHF
CLF
CLP
CNH
CNY
COP
CRC
CUC
CUP
CVE
CZK
DJF
DKK
DOP
DZD
EGP
ERN
ETB
EUR
FJD
FKP
GEL
GGP
GHS
GIP
GMD
GNF
GTQ
GYD
HKD
HNL
HRK
HTG
HUF
IDR
ILS
IMP
INR
IQD
IRR
ISK
JEP
JMD
JOD
JPY
KES
KGS
KHR
KMF
KPW
KRW
KWD
KYD
KZT
LAK
LBP
LKR
LRD
LSL
LYD
MAD
MDL
MGA
MKD
MMK
MNT
MOP
MRU
MUR
MVR
MWK
MXN
MYR
MZN
NAD
NGN
NIO
NOK
NPR
NZD
OMR
PAB
PEN
PGK
PHP
PKR
PLN
PYG
QAR
RON
RSD
RUB
RWF
SAR
SBD
SCR
SDG
SEK
SGD
SHP
SLE
SLL
SOS
SRD
SSP
STD
STN
SVC
SYP
SZL
THB
TJS
TMT
TND
TOP
TRY
TTD
TWD
TZS
UAH
UGX
USD
UYU
UZS
VES
VND
VUV
WST
XAF
XCD
XCG
XOF
XPF
YER
ZAR
ZMW
ZWG
ZWL