Carboline Pyrocrete 341 - 22.7KG
Carboline Pyrocrete 341 - 22.7KG
Pyrocrete 341 A minimum average 52 lb./ft³ (833 kg/m³) density, portland cement-based fireproofing material that provides hydrocarbon pool fire, jet fire, and cryogenic spill protection for structural steel. Recommended areas of application include refineries, petrochemical, and LNG facilities.
Product Features
- UL 1709 hydrocarbon fire rated up to 4 hours
- ISO 22899-1 jet fire rated from 30 minutes to 2 hours
- ISO 20088-1 cryogenic spill protection to -50°C
- Resistant to 4 bar blast overpressure
- ISO 20088-1 cryogenic spill followed by ISO 22899-1 jet fire
- 4 bar overblast followed by third party witnessed hydrocarbon fire
- NFPA 290 simultaneous torch and hose stream resistant (extended to 150 minutes)
- UL 2431 Category I-A Outdoor Heavy Industrial and Exterior Environmental Purpose
- Lightweight - one-third the weight of concrete
- Ideal for field and shop application
- Enhanced application characteristics (3/4" - 1 1/2" (19 - 38.1 mm) on initial pass)
- Excellent durability with early hardness development
- Non-friable – high impact strength
- Asbestos-free – complies with EPA and OSHA regulations
| Color | Non-Uniform Speckled Gray Product color may vary due to variations in color of Portland cement. |
| Finish | Textured If a smooth finish is required, this may be done by trowel, roller or brush typically within 1 to 2 hours after final application of Pyrocrete 341. |
| Primer | Pyrocrete 341 neither promotes nor prevents corrosion. The fireproofing should not be considered as part of the corrosion protection system. For applications where primers are required, use a Carboline approved, alkaline resistant primer. Contact the Carboline Fireproofing Technical Service for further information and approved primers. |
| Application Thickness | 3/4" - 1 1/2" (19 - 38.1 mm) on initial pass |
| Theoretical Coverage Rates |
14.40 - 13.30 bd.ft/bag @ dry density range of 52 - 55 lb./ft³ (1.34 - 1.24 m2/bag @ range of 833 - 882 kg/m³) Field results will vary depending upon application parameters. Coverage based on theoretical gross yield without loss. Material losses during mixing and application must be taken into account when estimating project requirements. Coverage based on 50 lb. (22.7 kg) bags plus 4.5 gallons (17.0 liters) of water. (one board ft = one ft² of material at one inch thick, or 0.09 m² of material at 25.4 mm thick). |
| Limitations | Not recommended for use as a refractory cement or where continuous operating temperatures exceed 200°F (93°C). |
| Topcoats | Generally not required. In severely corrosive atmospheres, topcoats may be used for added durability and chemical resistance. Consult Carboline Fireproofing Technical Service for selection of the coating most suitable for the operating environment. Seal Coat – In corrosive environments, use an appropriate topcoat. If topcoating is required, apply Carboguard 1340 as a seal coat. Carboguard 1340 shall be thinned 25% with Carboline Thinner 76. Carboguard 1340 may be applied after 24 hours of final application of Pyrocrete 341. Consult the Carboguard 1340 Product Data Sheet for minimum and maximum cure times. Alternatively, the use of Carboguard 1340 WB is an acceptable sealer for Pyrocrete 341. Top Coat – Surface hardness should be a minimum Shore DO 64 as measured with a durometer prior to application of the topcoat. Caulking – For exterior installations, Acrilast Caulk II or approved equivalent should be applied at all termination joints between Pyrocrete 341 and any dissimilar surface. Contact Carboline Fireproofing Technical Service for full information. |
Data Sheets
Pyrocrete 341 PDS
Pyrocrete 341 SDS
Pyrocrete 341 - Application Guide (Revision C)
Pyrocrete 341 - Approved Primer List
The above information is based on current test data, health and safety information and application instructions supplied by our suppliers and manufacturers of the products. It is supplied for guidance and to the best of our knowledge is true and accurate. Customers should satisfy themselves to the suitability of the products in its intended use and no guarantee is given or implied as the conditions of actual use are beyond our control. If in doubt the customer should consult the designer of the project or the local building control.
Fire Stopping Shop, disclaim any liability for loss, damage or other expense which may arise from the use of this information, data or products refereed to and reserve the right to amend or change any details without notice. This statement does not affect your statuary rights.
AED
AFN
ALL
AMD
ANG
AOA
ARS
AUD
AWG
AZN
BAM
BBD
BDT
BGN
BHD
BIF
BMD
BND
BOB
BRL
BSD
BTN
BWP
BYN
BZD
CAD
CDF
CHF
CLF
CLP
CNH
CNY
COP
CRC
CUC
CUP
CVE
CZK
DJF
DKK
DOP
DZD
EGP
ERN
ETB
EUR
FJD
FKP
GEL
GGP
GHS
GIP
GMD
GNF
GTQ
GYD
HKD
HNL
HRK
HTG
HUF
IDR
ILS
IMP
INR
IQD
IRR
ISK
JEP
JMD
JOD
JPY
KES
KGS
KHR
KMF
KPW
KRW
KWD
KYD
KZT
LAK
LBP
LKR
LRD
LSL
LYD
MAD
MDL
MGA
MKD
MMK
MNT
MOP
MRU
MUR
MVR
MWK
MXN
MYR
MZN
NAD
NGN
NIO
NOK
NPR
NZD
OMR
PAB
PEN
PGK
PHP
PKR
PLN
PYG
QAR
RON
RSD
RUB
RWF
SAR
SBD
SCR
SDG
SEK
SGD
SHP
SLE
SLL
SOS
SRD
SSP
STD
STN
SVC
SYP
SZL
THB
TJS
TMT
TND
TOP
TRY
TTD
TWD
TZS
UAH
UGX
USD
UYU
UZS
VES
VND
VUV
WST
XAF
XCD
XCG
XOF
XPF
YER
ZAR
ZMW
ZWG
ZWL